Colocation Servers



COLOCATION SERVER IN DATA CENTER

PUT YOUR SERVERS AT MOST SECURED DATA CENTAR

Colocation is a service which allows you to storage server to secure data centar, designed to highest TIER 3 standards. Service includes storage your servers, energy and network access equipment


WHO NEEDS SERVICE COLOCATION OF SERVERS?



Company's which have existing server infrastructure lockated in inadequate areas

Company's which want no extra capital investments to use all benefits this services in terms of technical and secured availability with 0-24 support

Company's which want implement Disaster Recovery Site, and evade capital investments in technical and secured infrastructure, while at the same time they want to use their own equipment

Company's which operate at multiple locations (possibility of centralization of server infrastructure)

Company's which want to reduce the cost of maintaining server infrastructure


STRICTLY CONTROLLED AND SECURE DATA CENTER

PUT YOUR SERVERS IN THE DATA CENTER DESIGNED BY TIER 3 STANDARDS



Redundant air conditioning, warm-cold zone


Facility resistant to high loads and impact water


Uninterruptible power supply (UPS, generator, own substation)


Physical protection (access control, warning systems)


Fire protection (fire alarm system and automatic fire extinguishing with inert gas FM200)


Surveillance 24/7 (power, air conditioning, availability)


Physical and console access CO-located equipment


Certificate of ISO / IEC 27001: 2013 for corporate security departments and for cyber and data security. ISO 9001: 2008 for the management of corporate strategy and human resources.


Data center arranged according to TIER 3 standards (availability of 99.982%, 1.6 hours allowed unannounced interruptions per year; redundancy (N + 1))


In the package is included access CO-Located equipment (Internet, existing private or metro network). The user gets along with accommodation and a dedicated network access to its equipment.


Two independent circuit with an external telecommunications network - network infrastructure comes from two independent nodes.


SMART POWER DISTRIBUTION UNITS (SPDU) - “Smart” power strips within the rack - double-redundant power supply custom equipment.

WHY LOCATE SERVERS IN THE DATA CENTER?

DEDICATED ACCESS

Inside each package the user receives a dedicated network access to its equipment with the public IP address.
WITHOUT A GREAT COST

If you choose accommodation equipment in our data center, you avoid the huge capital investments to equip its own data center.
COMPLETE SOLUTION

By choosing our services you get a complete and quality solution that enables a single service provider.
SUPPORT

The monthly fee includes 24/7 technical support to our customer service.
INTERNATIONAL STANDARDS

Your equipment will be located within the data center space in high availability, which meets all the technical and safety regulations.


LEARN MORE ABOUT OUR DATA CENTER



LOCATION AND CONSTRUCTION
  • Data center (data center) is located in Zagreb.
  • Sufficient distance (over 100 meters) of gas stations and other stores poisonous, explosive, corrosive or similar materials.
  • Sufficient distance from the transport routes which are often transporting hazardous materials.
  • Site is constructed with an appropriate design documentation, consistent with the statutory regulations and the standardization.
  • The possibility of entry of heavy equipment is provided (access to the forklift and the cargo lift), door height 2.2 m, width up to 2 m.
  • In server rooms is built up under the double height of 90 or 60 cm, with the height of the raised floor to the
  • ceiling more than 300 cm. Raised floor is electrically grounded, and under this are sensors for water, moisture, fire, smoke, gas and dust. Raised submitted under uniformly distributed load up to a load of 1500 kN to 290 kN and spot-distributed load.


AIR CONDITIONING AND REFRIGERATION
  • The cooling systems consist of a combination of cooling water systems and air conditioning units installed in all data centers, so it is still installed, the redundant cooling cabinet system in each hall.
  • The temperature is maintained between 22 ± 2 ° C and humidity in the server rooms is in the range of 50 ± 20%. For each system there is room embedded system for fresh air supply is equipped with air filters, indicators of gas and fresh-air supply capacity of 1-2 changes per hour.
  • The system halls are installed cabinets for equipment which is achieved separation warm cold zones.


ELECTRICAL POWER
  • Power supply from the power grid is derived from its own substation via three independent medium voltage inputs by HEP.
  • Enough distance from the transport routes which are often transporting hazardous materials.
  • In particular, built-in redundant work diesels (DEA) individual power to 1100 kW for a backup power supply with underground seasonal storage tanks for fuel which allows continuous operation of the DEA to 72 hours.
  • Server uninterruptible power supply (UPS systems) is achieved in two independent fields of energy.
  • Enabled supply and user equipment from the system DC Uninterruptible Power Supply (DC system).


FIRE PROTECTION
  • Fire protection was carried out in accordance with NFPA 75 Standard for Protection of Electronic Computer / Data Processing Equipment: 1999 and LPC Recommendations for loss prevention and EDP and similar installations and the relevant Croatian legislation and normalization.
  • Each server room is realized as a separate fire compartment separated from the surrounding room walls and doors of the material fire resistance of at least 60 minutes, and sealing installation breakthrough toward neighboring areas in accordance with the DIN 4102 standard.
  • To prevent the spread of fire and smoke, the air conditioning system comprises fire dampers derived in accordance with Article 53 of the Regulations on technical standards for ventilation and air conditioning systems (OJ 38/39, taken NN 53/91) and with DIN 4102.
  • Implemented intelligent automatic fire alarm system with recording the history of the event; automatic detectors monitor the work area and premises suspended ceiling and raised floor; in compliance with the Rules on fire alarm systems (Official Gazette no. 56/99).
  • Automatic fire was achieved 'green gas' (Novec1230) premises server room space and a suspended ceiling and raised floor server room.
  • Rooms reserve power supplies, batteries, and diesel engines are designed as separate fire compartment separated from the surrounding room walls and doors fire resistance of at least 60 minutes; sealing installation breakthrough toward neighboring areas in accordance with the DIN 4102.
  • All technical systems of fire protection (fire alarm system, fire dampers, etc.) Have appropriate project documentation approved by the Ministry of Interior, the police department and certificate of functionality was issued on the basis of the system is tested by an authorized person, in accordance with Article 20 of the fire protection (Official Gazette No. 58/93) and accompanying regulations.

OUR DATA CENTER HAS HIGH INTERNATIONAL CERTIFICATES FOR INFRASTRUCTURE, SAFETY AND STAFF

  • The equipment will be located within the data center space high availability that meet the defined technical and safety standards (access control, fire protection, redundancy power and cooling).
  • 1. Certificate for the management system according to ISO / IEC 27001: 2013 for SUIS (ISMS) associated with providing customer service managed by the Department of Corporate Security and the Department of cyber and data security.
  • 2. ISO 9001: 2008 for the management of corporate strategy and business development as well as quality and Architecture.
  • 3. ISO 9001: 2008 for services in the field of management, development and human resources strategy and Labor Relations Management.
  • 4. Certificate Deutsche Telekom in the area of compliance data centers with international physical security standards, certified in 2015.


CHOSE COLOCATION SERVER CUSTOM MADE FOR YOUR OFFICE

BASIC
FULL
SPACE FOR ACCOMMODATION
1 RACK UNIT 40 RACK UNIT
FORCE PER UNIT GUARANTEED SITUATING
120 W 4 kW
BASIC SPEED ACCESS
1 Gbps 10 Gbps
IP ADRESS
2 64
BANDWIDTH
unmetered unmetered
MONTHLY FEE
65 € 1.600 €

SMART HANDS & EYES

BRONZE
SILVER
GOLD
LEVEL OF SUPPORT
Full Full Full
MONTHLY WORKS
Max 2h/month Max 5h/month Max 10h/month
MONTHLY FEE
50 € 100 € 200 €

HAVE MORE QUESTIONS?

  • What is colocation?

  • What is a data center?

  • What is meant by N + 1, 2N and like??

  • What is UPS?

  • What is Unit (1U)?